V676
®
/ V476
®
CONTROL CONSOLE USER MANUAL 207
Step-Level Timing
Timing can be programmed on a sequence step-level to control the step, attack, sustain, and decay for each step in
the sequence.
Note: When cues are included in sequences, the cue times will override step attack times, unless timing is disabled
by the Function Filter. (Refer to "Function Filter" on page 115.)
+ Step - The time between activation of a step and the next sequential step. This can also be controlled on a
universal level in the effects timing attributes (refer to "Effect-Level Timing" on page 205).
+ Attack - Transition time between current luminaire state and state dictated by the step action.
+ Sustain - How long the channels will execute the action.
+ Decay - Transition time out of a step into a background state. This is used only in a situation where the effect is in
Break mode and the attack and sustain times are longer than the total step time.
Step 1 Step 2
Decay
Background State
Step Time Step Time
Attack
Sustain
Attack
Sustain