DMX512 REFERENCE GUIDE
100 02.3004.0300.54
Table 4-3: VL6 Spot Luminaire Mechanical Tests
Test Number Test Parameter Error Codes/Comments
000
Start Test
9
End Stop (Open)
103
No Reset (Pan)
001
Pan Test
8
End Stop (Clsd)
203
No Reset (Tilt)
002
Tilt Test
7
Speed 1 (25%)
104
No Reset (Pan)
004
Edge Test
6
Speed 2 (35%)
204
No Reset (Tilt)
5
Speed 3 (45%)
4
Speed 4 (55%)
3
Speed 5 (65%)
2
Speed 6 (75%)
1
Speed 7 (85%)
0
Speed 8 (Full Speed)
005
Intensity Test
9
End Stop (Open)
511
Hit Sensor When Not Expect-
ing To.
8
End Stop (Clsd)
514
Did Not Hit Sensor When
Expecting To.
7
Speed 1 (25%)
6
Speed 2 (35%)
5
Speed 3 (45%)
4
Speed 4 (55%)
3
Speed 5 (65%)
2
Speed 6 (75%)
1
Speed 7 (85%)
0
Speed 8 (Full Speed)
006 Wheel 1 Test 9 CW 1 Frame to
Sensor
611 Hit Sensor When Not
Expecting To (WH1)
007 Wheel 2 Test 8 CCW 1 Frame to Sen-
sor (Oscillating)
614 Did Not Hit Sensor When
Expecting To (WH2)
7 CW 1 Frams to Sensor
(Oscillating)
711 Hit Sensor When Not Expect-
ing To (WH2).
6 CCW 1 Frame to Sen-
sor (Oscillating)
714 Did Not Hit Sensor When
Expecting To (WH2).
5 Continuous Frame Step Direction Opposite Of Spin.
4 Speed 1 spin
3 Speed 2 spin Spin Speeds Match Those
2 Speed 3 spin Achievable From Console.
1
Speed 4 spin