DMX512 REFERENCE GUIDE
112 02.3004.0300.54
* Motors 1-8 actuate the framing blades and Motor 9 rotates the framing device.
8 Display current most signifi-
cant digit (Xxxx) of the
reported encoder value.
Repeatedly monitored.
7 Display current most signifi-
cant digit (Xxxx) of the
reported encoder value.
Repeatedly monitored.
6 Display current most signifi-
cant digit (Xxxx) of the
reported encoder value.
Repeatedly monitored.
0 Display scrolling snapshot of
each digit of the reported
encoder. Repeatedly moni-
tored.
024 Form and Function 0 Display the form and func-
tion value of the luminaire.
For the VL7 Py=F10 should
be reported where Y is the
luminaire’s port number.
071-
079*
Shutter System Motor
Test (Motors 1-9)
0 Full speed (100%) framing
from open stop to closed stop
repeatedly
Shutter Motor Tests
1 motor cycling (85%) 071 Operates Motor 1
2 motor cycling (75%) 072 Operates Motor 2
3 motor cycling (65%) 073 Operates Motor 3
4 motor cycling (55%) 074 Operates Motor 4
5 motor cycling (45%) 075 Operates Motor 5
6 motor cycling (35%) 076 Operates Motor 6
7 motor cycling (25%) 077 Operates Motor 7
8 End stop motor cycling (65%)
(OPEN)
078 Operates Motor 8
9 End stop motor cycling (65%)
(CLSD)
079 Operates Motor 9
Table 4-9: VL7B/VL7UB Spot Luminaire Mechanical Tests (Continued)
Test Number Test Parameter Error Codes/Comments